STEP 2

a

WARNING: Potential high pressure vessel!
Before disassembling your actuator, ensure
that the valve or other actuated device is iso-
lated and is not under pressure.

Lift actuator from mounting adapter.

2

3.1.2 Remounting (Type B1/B4/B4E Base)

STEP 3

Ensure stem nut (#1-22) is secured inside actuator
drive sleeve with retaining ring (#1-23). Lower
actuator onto the mating component, making sure
to align stem nut key and keyway with mating
component.

3

1-23

1-22

STEP 4

Ensure that the actuator and mounting adapter
flange mating holes are aligned correctly.

4