MX-85/140 Maintenance and Spare Parts

FCD LMAIM1341-00

STEP 6

Leave contactor assembly unmounted in control
module compartment to allow space for terminal
block harness plug bundle to be threaded over the
top of the contactor assembly and pulled into the
control module cavity.

6

STEP 7

Reference Terminal Block Assembly procedures
to remount terminal block assembly into actuator.
(See Section 5.5.2.)

Before mounting the contactor assembly, ensure
the terminal block wiring harness bundle is posi-
tioned across the end of the contactor.

7

Terminal block

wiring bundle

STEP 8

Position the contactor assembly so that the keyhole
slots in the contactor mount-ing plate allow the M4
screw heads to pass through; shift the contac-
tor assembly until the screw heads seat in the
key slots. Tighten screws using 3 mm hex key to
secure assembly.