5a 5b, 2 remounting – Flowserve MX-85 Actuator User Manual

Page 31

Advertising
background image

Flow Control

Limitorque Actuation Systems

FCD LMAIM1341-00

MX-85/140 Maintenance and Spare Parts

23

4.2.2 Remounting

STEP 4

Lightly lubricate the O-ring (#5-15) and fit it to the
inner race of the declutch cover (#5-1).

4

5-15

STEP 5

Tip: Picture 5a shows proper alignment between
the cam and the clutch ring roller.

Fit the complete declutch assembly into the
actuator housing, slightly twisting, if necessary, to
remount into actuator.

5a

5b

Advertising