3 remounting – Flowserve MX-85 Actuator User Manual

Page 36

Advertising
background image

Flow Control

Limitorque Actuation Systems

28

MX-85/140 Maintenance and Spare Parts

FCD LMAIM1341-00

STEP 5

Removing worm shaft assembly.
Remove adapter plate, then remove worm assembly.

NOTE: When removing the side-mounted hand-
wheel, the inner bearing (#13-8) should remain in
place in the housing.

Rotate the handwheel assembly clockwise (CW)
to withdraw the complete worm shaft plate
subassembly.

5

STEP 6

If needed, remove the handwheel worm gear
assembly (#12). (See Section 4.8.2 for removal
procedure).

6

Handwheel

Worm Gear Adapter (12-1)

4.3.3 Remounting

STEP 7

Check that bearing (#13-8) is correctly in place in
the actuator housing, it is press fit in the housing.

7

Advertising
This manual is related to the following products: