L3149B (C200) Advanced Tone Remote Desk Set

Installation

31

Line Connections for Local Control (L3147A) Operation

When programmed for local operation (L3147A) the desk set provides extended local control of the
radio. This operation requires PTT and monitor to be connected to J701 of the relay module in the base
of the desk set as noted in the chart below. Additionally, if parallel L3149B Desk Sets (in local control
mode) are to be used, the connection of PTT Sense and Monitor Sense allows proper operation of the
system. If a CDM1550 LS Mobile Radio is used, the clear-to-send of the radio must be connected to the
clear-to-send input that has been configured with the programming software.

The table below shows the connections that must be made between the L3149B relay module and the
radio. The items in bold are pertinent connections. Also note that the radio must provide the appropriate
pull-up (>= 47 kilohms) for proper operation.

J701 Pin Description

Connect To:

1

Programmable Input

CTS input (CDM1550 LS LTR Support)

2 Ground

Return

Radio Ground (same as pin 24)

3

Monitor Sense Input

Pin 13 if parallel units used

4

PTT Sense Input

Pin 16 if parallel units used

5

Programmable Input

CTS input (CDM1550 LS LTR Support)

6

Relay 4-1 N/C Contact

7

Relay 4-1 Common

8

Relay 4-1 N/O Contact

9

Relay 4-2 N/C Contact

10

Relay 4-2 Common

11

Relay 4-2 N/O Contact

12

Relay 3 N/C Contact

13

Monitor Output

Radio Monitor Input

14

Relay 3 N/O Contact

Pin 2 or 24

15

Relay 2 N/C Contact

16

PTT Output

Radio PTT Input

17

Relay 2 N/O Contact

Pin 2 or 24

18

Relay 1-1 N/C Contact

19

Relay 1-1 Common

20

Relay 1-1 N/O Contact

21

Relay 1-2 N/C Contact

22

Relay 1-2 Common

23

Relay 1-2 N/O Contact

24

Ground Return

Radio Ground (same as pin 2)

Advertising