Programming

L3149B (C200) Advanced Tone Remote Desk Set

52

PTT Sense

When configured for local control and with parallel units, the operator is not allowed to transmit during
the transmission of a parallel unit. This input allows the desk set to sense parallel transmissions and
lock-out transmissions until the parallel transmission is over. When this input is asserted, pulled to
ground, the

TRANSMIT

LED flashes. When the input is disasserted, the

TRANSMIT

LED extinguishes.

N

OTE

: This option is available only if the Type of Interface is Local.

LTR CTS

When configured for local control (L3147A) and using a CDM1550 LS Mobile Radio, the unit requires
an input to indicate that a channel has been established. The CDM1550 LS Mobile Radio provides an
output for this. When

TRANSMIT

is pressed, the unit waits for Y ms, (where Y is 1000 to 5000 ms in

50 ms

increments) for this input to be asserted. Upon assertion, the unit qualifies the assertion for X ms

(where X is 0 to 1000 ms in 10 ms increments).

Once qualified, the transmission begins and the

TRANSMIT

LED lights. If no assertion is received in the

programmed amount of time, “SYS NOT AVAIL” is displayed and the transmission is not made.

N

OTE

: This option is available only if the Type of Interface is Local.

Relay Outputs

A relay output can not be assigned if a programmable button set as Supv. via Relay is linked to it.

Disabled

When Disabled is selected, the output has no function.

E&M M-Lead

When the Type of Interface is configured as an E&M control or as an E&M with Tone control, a
closure is needed to act as the M-lead for transmission. The M-Lead is closed for any non-intercom
transmission.

N

OTE

: This option is available only if Type of Interface is E&M or Tone with E&M.

MDC Emergency

When a MDC emergency is decoded by the unit and the units is configured has Emergency Enabled
and also has Emergency Alarm Enabled, this output is asserted. The output is disasserted when the
emergency is cleared.