Monitor, Relays asserted, Configure paging – GAI-Tronics L3149B C200 Advanced Deskset User Manual

Page 59: To enable a paging type, To disable a paging type, To change the order of selected paging types

Advertising
background image

L3149B (C200) Advanced Tone Remote Desk Set

Programming

53

Monitor

When the Type of Interface is Local control, a monitor closure is necessary to place the radio in to
monitor mode. This monitor relay is configured as a normally open momentary relay and is asserted
when the

MONITOR

button is pressed and disasserted when the

MONITOR

button is not pressed. Note

that the relay also contains a normally closed contact.

PTT

When the Type of Interface is Local control, a PTT closure is necessary to place the radio in to
transmit mode. This PTT relay is configured as a normally open momentary relay and is asserted when
the

TRANSMIT

button is pressed and disasserted when the

TRANSMIT

button is not pressed. Note that

the relay also contains a normally closed contact.

Relays Asserted

Assign which relays are asserted when the relay's state changes.

N

OTE

: This is assignable only when a relay output is set to something other than Disabled. Also,

multiple relays can be assigned to one operation as well as multiple operations being assigned to a single
relay. In the latter configuration, the relay is affected by the last operation only.

Configure Paging

This feature allows the selection of paging types available to you in the paging menu. You may also
determine the order in which the selected paging types appear. Paging types enabled here have no effect
on which paging types are available in any part of the software. All paging types will be available.

To Enable a Paging Type

Highlight the paging type's name under Available Paging Types. More than one may be selected.
Click on the Add button. The name(s) move to the Paging Types in Use area. The new entry or
entries are placed at the end of the list.

To Disable a Paging Type

Highlight the paging type's name under Paging Types in Use. More than one may be selected. Click
on the Remove button. The name(s) move to the Available Paging Types area.

To Change the Order of Selected Paging Types

Highlight only one paging type under Paging Types in Use. Click on Move Up to place it higher on
the list. Click on Move Down to move it lower in the list. Click on an area of the window for a
description of its function.