8 Port CommVerter Operation and Installation Manual
84
N
N
O
O
T
T
E
E
In cases where unit's IP is unknown or there is no
Ping to the unit, proceed as follows:
1. Turn OFF the unit
2. Short CN8 jumper pins 4 and 6 (see Figure 3-5)
3. Turn the unit back ON
4. Browse to the default IP address 192.168.1.108 to
view the current settings
1. Power OFF the unit
2. Short jumper CN8 pins 2 and 3
3. Power ON the unit
4. Connect the CommVerter to a PC (LAN Connection)
5. Open the Web browser, and enter the IP address of the
Commverter. The Setup Main Screen is displayed (see Figure
3-6)
Figure 3-6. CommVerter Unit Setup Site – Main Screen
6. Click on Admin Tasks. The Admin screen is
displayed. Scroll down the page to reach the
TCP/IP timeouts section (see Figure 3-7)