5.1 Introduction to the operation

5.1.1 Control unit
The Programat EP 5010 is equipped with a wide-screen colour display. The furnace can be intuitively operated by means of
the membrane-sealed keypad and the touch screen. The touch buttons can be actuated by slightly tapping the display with
the fingertip and the furnace runs the desired function.

The user interface in the display is divided into three sections:
1. Information bar

(e.g. indication of the current furnace temperature, selected program type, etc.)

2. Main screen

(e.g. editing firing programs, changing the settings, etc.)

3. Navigation bar

(e.g. scrolling, scrolling to higher levels, opening favourite programs, etc.)

5.1.2 Explanation of the key functions

Key

Function

HOME key
Switch to home screen (main menu).

PROGRAM key
Press once: Display of the currently selected program.
Press twice: Switch to the program selection via number entry.

CHANGE OPERATING MODE key
By pressing this key, you can switch between the firing and the press mode.

IRT key
With this key, the infrared image of the object can be displayed during the closing
process.
POWER SAVING key
By pressing this key, the power-saving function is activated (only possible with the furnace
head closed and the furnace on idle). The display shows the power-saving icon. Pressing
any key ends the automatically activated power-saving function.
OPEN FURNACE HEAD key
Quick cooling with the furnace head open:
If the furnace head is completely open and the OPEN FURNACE HEAD key is pressed
again, the quick cooling function is activated. I.e. the vacuum pump is switched on for
5 minutes. This function can be stopped at any time by pressing the STOP, CLOSE
FURNACE HEAD or START key. This function can be activated any time when the furnace
head is open.

CLOSE FURNACE HEAD key