Operation and configuration – Ivoclar Vivadent EP 5010 User Manual

Page 25

Advertising
background image

25

– Selection list
In the selection list, the desired parameter can be selected by using the up / down

arrows. An entry must be confirmed with the green button. After that, the selection
list is closed.

The selection list can be closed with the red button, without any parameters being

changed.

5.1.5 Selecting the operating mode
The furnace can be operated in two different modes:
– Pressing:
Only press programs can be selected. The stand-by temperature of the furnace is set to 700 °C.
– Firing:
Only firing programs can be selected. For Ivoclar Vivadent programs, the stand-by temperature of the furnace is set to

403 °C.

In order to switch between the press and the firing modes, you must press the CHANGE OPERATING MODE key to change
the operating mode (Chapter 5.1.2).

Once the CHANGE OPERATING MODE key has been pressed, the operating mode can be selected.

1. Select the desired operating mode.

2. After the operating mode is selected, a note is displayed indicating
the different stand-by temperatures of the respective operating modes.

Switching from "Firing" to "Pressing": Make sure that the furnace
has heated up to 700 °C before starting the press program.

Switching from "Pressing" to "Firing": Make sure that the furnace
has cooled down to 403 °C before starting the firing program.

In the information bar, the operating mode is displayed in addition to the temperature.

Icon

Meaning
Operating mode "Pressing"
If this icon is displayed in the information bar, the operating mode "Pressing" is active.
In this operating mode, only press programs are available and the stand-by temperature
is set to 700 °C.
Operating mode "Firing"
If this icon is displayed in the information bar, the operating mode "Firing" is active. In
this operating mode, only firing programs are available and the stand-by temperature is
set to 403 °C.

5. Operation and Configuration

Advertising