5.1.6 Explanation of the home screen
After the furnace is switched on, the display shows the home screen. All functions of the Programat can be selected from
this screen. You can switch back to the home screen with the HOME key.

By pressing a selection button, you will reach the corresponding menu
(e.g. firing programs, settings, calibration, etc.).

By pressing the [Arrow] buttons, the next page of the home screen is
accessed, where additional functions are available.
The circles between the arrows indicate the number of pages.
The current page is marked with a light dot.

5.1.7 Explanation of the speaker signals
– Upon closing the furnace head below 100 °C

There is a risk of crushing when closing the furnace head. If the furnace head is closed below 100 °C, the user
is alerted to the hazard by an acoustic signal.

– Upon completion of the self-test
To inform the user that the automatic self-test has been successfully completed, a pre-set, not modifiable melody is

played.

– Furnace head open and temperature below 560 °C
To inform the user that the temperature in the open furnace head has dropped below 560 °C the selected melody is

played (5 seconds). Thus, the furnace head has sufficiently cooled down for the next program start. The acoustic signal
can be stopped by pressing the STOP key.

– Furnace head open and temperature below 360 °C
To inform the user that the temperature in the open furnace head has dropped below 360 °C, the selected melody is

played. If the first playback (10 seconds) is not acknowledged with the STOP key, a second playback sounds after
5 minutes (for 5 minutes) to signal that the furnace head is cooling down. After that, no further signal is played.

If one of the two playbacks is acknowledged with the STOP key, the signal transmitter is switched off and no further

signals will be sounded.

– For error messages
Error messages are acoustically supported with the 'error melody' (endless beep). The acoustic signal can be confirmed

by pressing the STOP key, while the error message still remains visible. If the error message is acknowledged with the
corresponding button, the signal transmitter is also switched off.

– For active press cycle
To inform the user that the press cycle has been started, a pre-set, not modifiable melody is played.

– Upon completion of the press program
To inform the user that the press program has been completed, the selected melody is played continuously.