5.2.7 Starting and stopping programs / the operating indicator
Once the program is started by pressing START, the firing curve display appears.

The following information is displayed:

– Information bar
The program name and the current furnace temperature are shown in the information bar in the upper margin of the

display.

– Main area
The vacuum is shown on the left side of the main screen. The progress of the program is shown in the form of a firing

curve. The estimated remaining time is also displayed in 10-second intervals. If no vacuum is activated, the vacuum
indicator and all the corresponding parameters are blank.

The process status is displayed in colour in the firing curve:
– Orange: Program is closing the furnace head or is in predrying mode.
– Red: Program is heating up or is in holding time mode.
– Blue: Program is in long-term cooling or is opening the furnace head.

Active firing program options are shown in the grid next to the [Options] button.
If a two-stage program is selected, the firing curve is shown in two stages.