7. Maintenance, Cleaning and Diagnosis

1

2

7.6 Replacing the press plunger

The press plunger may be replaced if required. In order to facilitate replacing the press plunger, the following procedure
must be followed:

Step 1:
Remove the attachment screw.
Remove the screw (C) while the furnace head is closed.

Step 2:
Remove the press drive cover.
First firmly push the cover to the back (arrow 1) and then remove it
by lifting it (arrow 2).

Step 3:
Loosen the press plunger.
Unscrew the clamping screw of the press plunger (64) by turning it
approx. one half turn.

63

65

64