Quick set-up, Getting started, Terminal parameters – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual

Page 17: Logging on, Quick set-up -1, Getting started -3, Terminal parameters -3 logging on -3, Chapter

Advertising
background image

Verilink DPRI 2922

2-1

Chapter

2

Quick Set-Up

This chapter provides step-by-step procedures as an example for
setting up your DIDCSU 2912 module.

NOTE: Since the following procedures may not exactly apply to your

specific application, use them only as as a guide for the

configuration process. Complete descriptions of the various screen

options and suggestions for their applicability to your situation are

given in the following chapter.

NOTE: For the most effective and efficient set-up, have all required

planning data such as your intended use, network (telco) provider

specifications, channel and line requirements, circuit

configurations, and other important information handy. For your

convenience, worksheets are provided in the AS2000 Basics Manual,

Chapter 2—Site Planning.

Getting Started

After the NCM and DIDCSU modules and their NIM/CIM have been
installed in their appropriate shelf/slots (self-test has been
successfully completed), connect the Craft Interface Cable
(P/N 458-501788-008) to the Local port on the NCM front panel to
access the ASCII interface.

Terminal

Parameters

Terminal parameters: 19.2 kbit/s baud rate, 8 data bits, no parity,
one stop-bit, and no flow-control. Make sure that the X-On/X-Off
flow control is disabled.

Logging On

1. Press E

NTER

to display the pSH+> prompt and type craft.

2. Press E

NTER

to display the NCM Main Menu.

If the NCM Main Menu display

Figure 2-1

shows the DIDCSU in the

proper shelf/slot position, you may continue with the
configuration tasks.

The default password for the NCM will give the user Access Level 2
permissions. If you need a higher access level, see your NCM 2000
User Manual
for more information.