Bus compatibility, Bus compatibility -3 – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual
Page 18

Quick Set-Up
2-2
Verilink DPRI 2922
Bus
Compatibility
If there is no indication of the DIDCSU on the “shelf map” on the
NCM Main Menu, the modules may be assigned to different busses
on the shelf backplane.
NCMs are usually sent out with their default bus being the C bus.
Other modules usually are sent out with their default bus being the
A bus.
Assign the DIDCSU to the bus on which the NCM resides by
accessing the DIDCSU’s ASCII port directly.
1. Connect the Craft Interface Cable directly to the LOCAL port
on the DIDCSU module.
2. At the prompt, type craft, then press E
NTER
.
3. At the
PASSWORD:
PASSWORD:
PASSWORD:
PASSWORD: prompt, type “verilink”.
4. From the DIDCSU Main Menu, select the following:
ACE Controller Menu>
O) ACE Controller Administration Menu>
B) Change the ACP Bus
5. Once the bus assignment has been made, reboot the
reassigned module by either
•
Using the
Reboot
Reboot
Reboot
Reboot command from the ACE Controller
Administration Menu, option R, or
•
Reseating the module in its slot.
Reconnect to the NCM Local port for further operations.