Quick Set-Up

Verilink DPRI 2922

2-7

Figure 2-5 Configuration Menu (Timing Options)

2. All primary and dial-backup circuits must use shelf timing to

synchronize with each other; therefore, select R, then YES,
then refresh the screen by exiting to the T1 Port
Configuration Menu and then returning to the screen by
selecting T. When the

R)

R)

R)

R) “Receive clock from shelf” option has

been selected to be YES, the Configuration Menu (Timing
Options) menu displays as shown in Figure 2-4.

3. Use the ISDN network ports as the primary and secondary

sources. Use INTERNAL as the tertiary source. For example, if
the DIDCSU 2912 is in slot 2, the shelf timing table should look
like Figure 2-4. Exit to the Configuration Menu.

NOTE: Ensure that the card used as a timing source is set to Receive Clock

From Shelf as well.

Data Port Configuration

After both the DIDCSU module network ports have been properly
configured, continue with the data port configuration. You need to
know the types of equipment that will be connected to your data
ports and the interfaces that they will need. Refer again to the
filled-out checklists and worksheets.

1. From the NCM ASCII interface Main Menu (with the DIDCSU

designated as the active card), select option C,
“Configuration”, to start the configuration task.

Figure 2-6 Configuration Menu

2. From the Configuration Menu, select option D to access the

Data Port Configuration Menu.

-- DIDCSU 2912 CONFIGURATION MENU (TIMING OPTIONS)--

Current shelf timing source: Card 2, INTERNAL (PRIMARY)

Source Slot Number Synchronization Auto Restore

PRIMARY PC) 2 PS) NET1 PA) YES

SECONDARY SC) 2 SS) NET2 SA) YES

TERTIARY TC) 2 TS) INTERNAL TA) YES

R) Receive clock from shelf: YES

X) exit this screen

A [127.255.255.0] [1,2] DIDCSU 2912 >

A [127.255.255.0] [1,2] DIDCSU 2912 > c

-- DIDCSU 2912 CONFIGURATION MENU --

P) T1 port D) data port

I) ISDN PRI X) exit this screen

A [127.255.255.0] [1,2] DIDCSU 2912 >