Configuring the DPRI 2922 Via the NCM 2000 Craft Interface

3-38

Verilink DPRI 2922

Figure 3-27 Net Port Alarm Threshold Status

Circuit Manager Menu

To access the Circuit Manager Menu from the Main Menu, enter

B

.

Use the Circuit Manager menu to build and maintain circuits. A
circuit is the path on which data travels between a port at the
source end and a port at the destination end. The port can be a T1
or data port. T1 port circuit size is in number of timeslots, 1
through 24. The data port circuit size is in 56k or 64k bit
increments.

You can mix T1 and data ports as source and destination ends.
Data-to-data port circuits are limited to inter-module only.

For ISDN (dial backup switch) circuits, the ISDN port must be the
destination port. (Data ports are usually the source ports and net
ports are usually the destination ports.)

[0.0.0.5] [1,2] DPRI 2922 > s

-- DPRI 2922 NET PORT ALARM THRESHOLD STATUS MENU --

Current Threshold Status PORT 1 PORT 2

LOF counts(exceeded) 0(N) 0(N)

interval 0 0

LOS counts(exceeded) 0(N) 0(N)

interval 0 0

RAI counts(exceeded) 0(N) 0(N)

interval 0 0

AIS counts(exceeded) 0(N) 0(N)

interval 0 0

BPV counts(exceeded) 0(N) 0(N)

interval 0 0

ES 15min counts(exceeded) 0(N) 0(N)

ES 24hr counts(exceeded) 0(N) 0(N)

SES 15min counts(exceeded) 0(N) 0(N)

SES 24hr counts(exceeded) 0(N) 0(N)

Rn) Reset Registers X) exit this screen

[0.0.0.5] [1,2] DPRI 2922 >