Configuring the DPRI 2922 Via the NCM 2000 Craft Interface

Verilink DPRI 2922

3-41

Figure 3-29 Add Circuit Submenu

Table 3-24

Add Circuit Submenu Commands

Command

Description

Options

N

Name—Circuit name (Circuit ID

12 characters

maximum

P

Priority—

1) low

2) norm

3) high

4) crit

T

Type—Circuit type.

1) perm

2) swit

3) prim

4) d-bk

5) bkup

M

Mode—Circuit Mode

1) 64K

2) 56K

For Subrate DIU

only:

3) 38.4K

4) 19.2K

5) 9.6K

6) 4.8K

7) 2.4K

SP

Source Port—Displays the Node “Map” and prompts for the SRC Port shelf,

slot. Use this option to designate the starting point of your circuit. Once

the Shelf and slot position of the Source Port has been entered, you are

prompted with 4 choices.

1) net1

2) net2

3) dat1

4) dat2

DP

Destination Port—Displays the Node “Map” and prompts for the DEST Port

shelf, slot. Use this option to designate the ending point of your circuit.

Once the Shelf and slot position of the Source Port has been entered, you

are prompted with 4 choices.

1) net1

2) net2

3) dat1

4) dat2

SM

SRC Port Chn—Source Timeslot. Designate which T1 timeslots you wish to

use in this circuit.

Note: In ISDN, timeslot 24 is normally reserved for use in D-channel call

set-up. For this reason, avoid building circuits which use timeslot 24.

For ISDN, a call-reference option is provided to designate the call profile

for backup.

1—24 or press

ENTER

to exit

A [127.255.255.0] [1,2] DPRI 2922 > a

Add Circuit -- [1,1] NCM 2000 Firmware 4.15 --

N) Name: -- P) Priority: norm

T) Type: -- M) Mode: --

SP) [-,-] undefined DP) [-,-] undefined

SM) --src port chn-- DM) --dst port chn--

(undefined port) (undefined port)

(undefined port) (undefined port)

(undefined port) (undefined port)

(undefined port) (undefined port)

U) Bus: -- ->-->>->> Circuit Inactive <<-<<--<-

S) Setup X) Exit

A [127.255.255.0] [1,2] DPRI 2922 >