Interpreting front panel leds, Network leds, Interpreting front panel leds -6 – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual

Page 84: Network leds -6

Advertising
background image

Troubleshooting

4-6

Verilink DPRI 2922

Interpreting Front Panel LEDs

The LED indicators on the front panel of the DPRI 2922 module
display errors caused by network line or data terminal equipment
problems. The errors are reflected in the alarm status and the
performance/status menus in the ASCII terminal interface. Node
Manager also has an alarm display.

There are five LEDs on the front panel:

Two network port LEDs

Two data port LEDs

One system LED

Figure 4-2 DPRI Front Panel Showing Alarm Indicator LEDs

Network LEDs

Network LEDs display minor, major, and catastrophic alarm
conditions detected on the network line.

Table 4-2

Network LED Indicators

EXT

PRI

MANAGEMENT

SYS

LOCAL

2

NET

DATA

1

2

1

DPRI 292

Port LEDs

System LED

State

Color

Alarm Class

Action/Possible Error Condition

Solid

Green

All okay

None

Solid Amber

Diagnostic
mode with no
errors

None

Flashing

Amber and
Red

Yellow Alarm

Check the diagnostic performance status or alarm status

displays. The Yellow Alarm indicates that the unit is

receiving an RAI Signal, which indicates that the far end is

not receiving a signal from the near end.

Solid

Red

Major

Check the performance status or alarm status display. Loss

of Signal (LOS) from far end transmits all-ones.

Off

None

None

Port is not enabled.