Table 3-27 – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual

Page 75

Advertising
background image

Configuring the DPRI 2922 Via the NCM 2000 Craft Interface

Verilink DPRI 2922

3-45

Table 3-27

Edit Circuit Submenu Commands

Command

Description

Options

N

Name—Circuit name (Circuit ID)—12 characters maximum

P

Priority—

1) low

2) norm

3) high

4) crit

T

Type—Circuit type.

1) perm

2) swit

3) prim

4) d-bk

5) bkup

M

Mode—Circuit Mode

1) 64K

2) 56K

For Subrate DIU

only:

3) 38.4K

4) 19.2K

5) 9.6K

6) 4.8K

7) 2.4K

SP

Source Port—Displays the Node “Map” and prompts for the SRC Port shelf,

slot. Use this option to designate the starting point of the circuit. Once the

Shelf and slot position of the Source Port has been entered, you are

prompted with 4 choices.

1) net1

2) net2

3) dat1

4) dat2

DP

Destination Port—Displays the Node “Map” and prompts for the DEST Port

shelf, slot. Use this option to designate the ending point of the circuit.

Once the Shelf and slot position of the Source Port has been entered, you

are prompted with 4 choices.

1) net1

2) net2

3) dat1

4) dat2

SM

SRC Port Chn—Source Timeslot. Designate which T1 timeslots you wish to

use in this circuit.

Note: In ISDN, timeslot 24 is normally reserved for use in D-channel call

set-up. For this reason, avoid building circuits which use timeslot 24.

For ISDN, a call-reference option is provided to designate the call profile

for backup.

1—24 or press

ENTER

to exit

DM

DST Port Chn—Destination Timeslot Designate which T1 timeslots you

wish to use at the Destination Port.

Note: In ISDN, timeslot 24 is normally reserved for use in D-channel call

set-up. For this reason, avoid building circuits which use timeslot 24.

For ISDN, a call-reference option is provided to designate the call profile

for backup.

1—24 or press

ENTER to exit

U

Bus—Select a backplane bus for intermodule communication. The A Bus is

always used for ISDN.

1) A

2) B

3) C

4) Auto

A

Primary circ—Primary Circuit Name

12 characters

maximum

Advertising