Regulatory requirements, Regulatory requirements -5 – Verilink HDM 2180 (880-503048-001) Product Manual User Manual

Page 15

Advertising
background image

HDM 2180 DS3 DSU Overview

Verilink HDM 2180 User Manual

1-5

Table 1-2

Data Port Specifications

Table 1-3

Environmental Specifications

Regulatory

Requirements

This product complies with the following regulatory specifications
as they apply to telecommunications equipment:

FCC—Part 15, Subpart J, Class A: Computing devices

15.810: Radiated Emission

Input Signal

-11.7 dBm to +6.2 dBm, level DS3

Output Signal

-4.7 dBm to +3.6 dBm (DSX-3 cross-connect point)

Impedance

75

± 5%

Connector

BNC female, one each for TX and RX

System Timing

T3 (BNC), Network, or Internal

Data Ports

Type

HSSI, DCE only

Line rate

n

×

1.578 Mbit/s, where n = 1 to 28

Physical interface

50-pin HSSI

Hardware handshake

Control leads supported for DTR, DSR, TM, LLA, LLB

Non-operating

Temperature range

-20 to + 80

°

C

Maximum

temperature change

rate

8

°

C

per hour

Humidity

0% to 95% relative, non-condensing

Vibration, in

transport, withstand

0.5 G from 5 Hz

3.0 G from 50 Hz to 500 Hz

Shock during

shipping, withstand

20 msec, 25 G, half-sine shock pulse when mounted normally

80 G peak, half sine for 10 msec

Operating

Power consumption

<15 Watts total, front and back modules

Temperature range

0 to 50

°

C

, 0% to 95% relative humidity, non-condensing

Vibration

Withstand 25 G @ 1 to 60 Hz with no service interruption

Advertising