Alarm monitoring, Alarm monitoring -20, Figure 3-15 – Verilink HDM 2180 (880-503048-001) Product Manual User Manual

Page 44

Advertising
background image

Standalone HDM 2180 Management

3-20

Verilink HDM 2180 User Manual

Alarm

Monitoring

To see real-time, continuous alarm notifications, from the Main
Menu, select:

R) monitor alarms

to display the Alarm Monitoring screen:

Figure 3-15 Alarm Monitoring Menu

Below the title of the Alarm Monitoring Menu, there is a descriptor
telling which alarm buffer each real-time alarm will be stored in.

Each listed alarm will have a T, D, or L displayed in front of it. “T”
alarms are stored under the “View alarm buffer” option found in
the Main (top level) Menu. “D” alarms are stored under the “Display
Diagnostics Loopbacks History” option in the Diagnostics Menu.
“L” alarms are stored under the “Display Diagnostics Alarms
History” option, also in the Diagnostics Menu.

If no alarms are active, the display is empty.

Once you press E

NTER

or you exit the real-time alarm display, the

alarm message can be found in its respective buffer and is no
longer visible in the real-time alarm monitoring screen.

P

DS3 Port Configuration—Sets the DS3 Port Configuration to the manufacturing defaults.

HDM > p

Set DS3 Port Configuration to Manufacturing Default? (Y/N) >y

DS3 Port Configuration value set to Default.

System could be in Unknown State. Please REBOOT the board!!

S

SNMP Configuration—Sets the SNMP Configuration to the manufacturing defaults.

HDM > s

Set SNMP Configuration to Manufacturing Default? (Y/N) >y

SNMP Configuration value set to Default.

System could be in Unknown State. Please REBOOT the board!!

H

HSSI Port Configuration—This option sets the HSSI Port Configuration to the

manufacturing defaults.

HDM > h

Set HSSI Port Configuration to Manufacturing Default? (Y/N) >y

HSSI Port Configuration value set to Default.

System could be in Unknown State. Please REBOOT the board!!

X

exit menu—Returns you to the Main Menu,

Figure 3-1

.

Command Description

HDM > r

HDM > r

HDM > r

HDM > r
------ ALARM MONITORING ------

------ ALARM MONITORING ------

------ ALARM MONITORING ------

------ ALARM MONITORING ------
T: top menu alarms - D: diagnostics alarms - L: loopback alarms

T: top menu alarms - D: diagnostics alarms - L: loopback alarms

T: top menu alarms - D: diagnostics alarms - L: loopback alarms

T: top menu alarms - D: diagnostics alarms - L: loopback alarms
(Hit X to exit or Return to erase the screen)

(Hit X to exit or Return to erase the screen)

(Hit X to exit or Return to erase the screen)

(Hit X to exit or Return to erase the screen)
T: alarmlog num=15; 1-29-1997;7:15:11;(1/4 hour)DS3 UAS alert cross the threshold

T: alarmlog num=15; 1-29-1997;7:15:11;(1/4 hour)DS3 UAS alert cross the threshold

T: alarmlog num=15; 1-29-1997;7:15:11;(1/4 hour)DS3 UAS alert cross the threshold

T: alarmlog num=15; 1-29-1997;7:15:11;(1/4 hour)DS3 UAS alert cross the threshold
T: alarmlog num=16; 1-29-1997;7:15:11;(1/4 hour)DS3 FE UAS alert cross the threshold

T: alarmlog num=16; 1-29-1997;7:15:11;(1/4 hour)DS3 FE UAS alert cross the threshold

T: alarmlog num=16; 1-29-1997;7:15:11;(1/4 hour)DS3 FE UAS alert cross the threshold

T: alarmlog num=16; 1-29-1997;7:15:11;(1/4 hour)DS3 FE UAS alert cross the threshold

Advertising