Standalone HDM 2180 Management

3-14

Verilink HDM 2180 User Manual

Performance Monitoring Menu

Pressing P from the Main Menu displays the Performance
Monitoring menu. This menu allows you to see the 24-hour and
quarter-hour (15-minute) performance of the selected module for
the near end (NE) and a locally-limited set of information for the far
end (FE).

L

Transmit FEAC DS3 LOS/HBER Alarm—A LOS failure is declared when an incoming LOS

defect persists during a range of 2 to 10 seconds. The LOS failure is cleared when the

LOS defect is absent for 20 seconds.

HDM > l

Perform LOS Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

O

Transmit FEAC DS3 Out-of-Frame—A Loss of Frame (LOF) failure is declared when the

OOF defect persists during a range of 2 to 10 seconds. The LOF is cleared when the OOF

defect is absent for 20 seconds.

HDM > o

Perform FEAC OOF Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

R

Transmit FEAC DS3 AIS Received—An Alarm Indication Signal failure is declared when an

incoming AIS defect persists during a range of 2 to 10 seconds. The AIS is cleared when

the AIS defect is absent for 20 seconds.

HDM > r

Perform AIS Receive Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

I

Transmit FEAC DS3 Idle Received—An Idle Signal condition is declared when the Idle

Signal persists for 2 to 10 contiguous 1-second intervals. The Idle Signal condition is

cleared when it has been absent for 20 seconds.

HDM > i

Perform FEAC IDLE Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

C

Transmit FEAC DS3 Common Eqpt. Fail—Conditions to cause activation of this FEAC

signal alarm are not defined for this module.

HDM > c

Perform Transmit Common Equipment FAIL Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

P

Transmit FEAC DS3 EQUIPMENT FAILURE (NSA)—Conditions to cause activation of this

FEAC signal alarm are not defined for this module.

HDM > p

Perform EQUIP FAIL (NSA) Alarm(Y/N)? y

Enter choice(0 for Enable or 1 for Disable) >

X

exit menu—Returns you to the Diagnostics Menu,

Figure 3-6

.