120
Model
MPU
slots
Switching
fabric
module slots
LPU
slots
Fan
trays
Power
frames
Recommended
number of power
supplies
Max input
current
S12508-AC
2 9
8 2 1 3
to
6
21.6A@220
VAC
43.1A@110
VAC
S12508-DC
2 9
8 2 1 3
to
6
100A@48
VDC
S12518-AC
2 9
18
2 2 6
to
12
48.6A@220
VAC
97.1A@110
VAC
S12518-DC
2 9
18
2 2 6
to
12
225.2@48V
DC
NOTE:
•
The "AC" suffix in a chassis model represents AC powered and the "DC" suffix in a chassis model
represents DC powered.
•
The LPU slots are for both Ethernet interface cards and OAA cards. For card specifications, see
specifications and compatibility
.
Card specifications and compatibility
Category Card
model Description
Applicable
S12500 chassis
Supported
quantity
MPU
LST1MRPNC1
S12500 MPU
All S12500 models 1 to 2
Switching
fabric
module
LST1SF08B1
S12500 switching fabric module S12508 7
to
9
LST1SF18B1
S12500 switching fabric module S12518 7
to
9
LST2SF08C1
S12500 switching fabric module
S12504 and
S12508
3 to 4 (S12504)
7 to 9 (S12508)
LST2SF18C1
S12500 switching fabric module S12518 7
to
9
Ethernet
interface
cards
LST1XP16LEB1
16-port 10 Gbps fiber Ethernet
interface card (Standard)
All S12500
switches installed
with LST2SF18C1
or LST2SF08C1
As required
LST1XP16LEC1
16-port 10 Gbps fiber Ethernet
interface card (Enhanced)
All S12500
switches installed
with LST2SF18C1
or LST2SF08C1
As required
LST1XP16LEC2
16-port 10 Gbps fiber Ethernet
interface card (Enhanced)
All S12500
switches installed
with LST2SF18C1
or LST2SF08C1