Table 18 Command output

Field Description

Slot

In standalone mode:
Slot—A number in this field indicates a card.

In IRF mode:

Slot—The chassis-number/slot-number in this field indicates a card on an IRF member

switch.

Sensor

Temperature sensor:

hotspot—Hotspot sensor.

inflow—Air inlet sensor.

outflow—Air outlet sensor.

Temperature Current

temperature.

Lower limit

Lower temperature threshold.

WarningLimit

Warning temperature threshold.

AlarmLimit

Alarming temperature threshold.

ShutdownLimit

Shut-down temperature threshold (currently not supported).

Isolating a card and locating card faults

When the switch detects a card failure or upgrades a logic of the CPU daughter card on a card, you can
isolate the faulty card or the CPU daughter card to prevent it from forwarding data packets. This

operation allows for convenient on-site fault location or upgrading while causing no interference on the

operation of the system and services of other cards.

Configuration restrictions and guidelines

The active MPU cannot be isolated.

If only one switching fabric module is working on the switch, it cannot be isolated.

Before upgrading a logic of the LPU, keep the LPU offline.

To minimize the interference on the system operation, force a switching fabric module that is
operating normally offline before you unplug it.

You can use the display device command to view whether a card is isolated, or, whether the card
is in the offline state.

No other commands but the test diag-offline command can be executed for an isolated card.
Otherwise, the configuration cannot take effect. After isolating a card, you can use the test

diag-offline command to collect the fault detection information of the card. The path where the fault

detection information is saved is also displayed following the fault detection information on the
terminal. For example, you can see flash:/diag_slot3_20080522_103458.txt.

Deliver the fault detection information to the H3C technical engineers or engineers of the sales
agent.

Configuration procedure

To isolate a card and locate card faults: