Enabling power supply management, Configuring the number of redundant power supplies – H3C Technologies H3C S12500 Series Switches User Manual

Page 75

Advertising
background image

65

DEVICE_SERIAL_NUMBER : 210235A36L1234567891

MAC_ADDRESS : NONE

MANUFACTURING_DATE : 2010-01-20

VENDOR_NAME : H3C

Enabling power supply management

If power supply management is not enabled when you add a new card by inserting it into the slot
or starting power supply to the card by using the power-supply command, the system directly

powers on the card, and the power supply may become unstable or the system may restart because

of overloading.

If power supply management is enabled when you add a new card by inserting it into the slot or
starting power supply to the card by using the power-supply command, the system compares the
maximum power consumption of the card against the available power (including the redundant

power supply). If the former is not greater than the latter, the system supplies power to the card,

otherwise, the system does not supply power to the card.

To enable power supply management:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable power supply
management.

In standalone mode:
power-supply policy enable

In IRF mode:

power-supply policy enable chassis chassis-number

Enabled by default.

Configuring the number of redundant power supplies

Redundant power supplies are reserved for power supply backup and power supply threshold alarming.

With multiple redundant power supplies configured in the system, if a power supply fails or the system
power supply is overloaded, the system automatically enables a redundant power supply. As a result, the

number of redundant power supplies decreases by one.
If power supply management is disabled, the system does not reserve any redundant power supply. In

this case, you can also use the power-supply policy redundant command to configure the number of
redundant power supplies, and this configuration will take effect after power supply management is

enabled.
To configure the number of redundant power supplies:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable power supply
management.

In standalone mode:

power-supply policy enable

In IRF mode:

power-supply policy enable chassis

chassis-number

By default, power supply
management is enabled.