Field Remarks

Transceiver info I/O error

Transceiver information read and write error

Transceiver info checksum error

Transceiver information checksum error

Transceiver type and port
configuration mismatch

The type of the transceiver module does not match the port
configuration.

Transceiver type not supported by
port hardware

The port does not support this type of transceiver modules.

# Display the currently measured values of the fault detection parameters of the transceiver plugged in

interface GigabitEthernet 3/0/1.

<Sysname> display transceiver diagnosis interface Gigabitethernet 3/0/1

GigabitEthernet3/0/1 transceiver diagnostic information:

Current diagnostic parameters:

Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)

36 3.31 6.13 -35.64 -5.19

Table 25 Command output

Field Description

transceiver diagnostic information Digital diagnosis information of the transceiver module on the interface.

Temp.(°C)

Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.

Voltage(V)

Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.

Bias(mA)

Digital diagnosis parameter—Bias current, in mA, accurate to 0.01 mA.

RX power(dBM)

Digital diagnosis parameter—RX power, in dBM, accurate to 0.01 dBM.

TX power(dBM)

Digital diagnosis parameter—TX power, in dBM, accurate to 0.01 dBM.