Power supply system failure

Power monitoring module

Table 26 Power monitoring module LED description

LED Status

Description

RUN

Steady on

The power monitoring module is operating properly.

Off

The power monitoring module is faulty.

MAJOR

Steady on

At least one power supply is faulty.

The switch of the power frame is off.

A power supply is present, but no AC power supply is provided.

Turns on and
then goes off

A power supply is being inserted or removed.

Off

The power supplies are operating properly.

MINOR Off

Reserved

To troubleshoot the failures when the RUN LED of the power monitoring module is off:

1.

Unplug and then plug the power monitoring module.

2.

If the RUN LED is still off, replace the power monitoring module.

3.

If the RUN LED is still off, contact H3C Technical Support for help.