Run led, Switching fabric module leds – H3C Technologies H3C S12500 Series Switches User Manual

Page 144

Advertising
background image

134

Table 55 Interface LED description

LED Status

Description

LINK/ACT

Steady on

A link is present.

Off

No link is present.

Flashing

Data is being transmitted and/or received on the interface.

RUN LED

Table 56 RUN LED description

LED Status Description

RUN (green-red)

Flashing green

The LPU is operating properly.

Flashing red

The LPU is faulty.

Steady on

The LPU is faulty.

Off

The LPU is faulty or not in position.

NOTE:

The RUN LED description of different S12500 LPU models is the same.

Switching fabric module LEDs

Table 57 Interface LED description

LED Status Description

LINK

Off

No link is present.

Steady on

A link is present.

ACT

Off

No data is being transmitted or received.

Flashing

Data is being transmitted and/or received.

Table 58 RUN LED description

LED Status

Description

RUN (green-red)

Flashing green

The switching fabric module is operating properly.

Flashing red

The switching fabric module is faulty.

Steady on

The switching fabric module is faulty.

Off

The switching fabric module is faulty or not in position.

NOTE:

The LED description of different S12500 switching fabric modules is the same.