Configuration procedure, Displaying the operating state of fans – H3C Technologies H3C S12500 Series Switches User Manual

Page 87

Advertising
background image

77

If a port is automatically shut down due to hardware failure protection, its status displayed with the

display interface command is Protect DOWN. To bring up the port, use the undo shutdown
command on the port.

If a card is isolated or its software is not allowed to be loaded due to hardware failure fix operations,
you can plug out the card and then plug it in to recover the card status.

After configuring in-service diagnosis and failure protection, you can use the display
hardware-failure-detection command to check the running information of the feature.

Configuration procedure

To configure in-service hardware failure diagnosis and failure protection:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable in-service

hardware failure
detection and

configure fix actions

taken in case of
hardware failures.

hardware-failure-detection
{ chip | board |
forwarding } { off | warning

| reset | isolate }

Fix actions for hardware failures:

off—Takes no action.

warning—Sends warning messages.

reset—Resets the failed card.

isolate—Shuts down the failed port, isolates

the failed card, prohibits the failed card from
loaded, or powers off the failed card to

reduce the impact of the failure to the system.

By default, the fix action taken for all hardware

failures is warning.

3.

Enable hardware
failure protection for

aggregation groups.

hardware-failure-protection
aggregation

Optional.
Disabled by default.
This command is effective only when the fix

action is configured as isolate.

4.

Enter Ethernet interface
view.

interface interface-type
interface-number

N/A

5.

Configure hardware
failure protection for

the port.

hardware-failure-protection
auto-down

Optional.
Disabled by default.
This command is effective only when the fix

action is configured as isolate.

Displaying the operating state of fans

Use the display fan command to display the operating state of fans on your switch.

In standalone mode:
# Display detailed information about all fans on the switch.

<Sysname> display fan verbose

Fan-tray 1:

Software version: 101

Hardware version: Ver.A

CPLD version: 001

Fan number: 12

Advertising