68

Step Command

Remarks

3.

Allocate new IDs for
the specified AC

power supplies.

In standalone mode:
power-supply module old-id-list new-id new-id-list

In IRF mode:

power-supply module chassis chassis-number
old-id-list
new-id new-id-list

By default, the
system allocates IDs

for AC power

supplies randomly.

Displaying the power supply system information about your
switch

Use the display power-supply command to display power supply system information about your switch,

including whether power management is enabled, the number of configured redundant power supplies,
power, output voltage and current, and whether each card is powered on.

In standalone mode:
# Display detailed information about the power supply system.

<Sysname> display power-supply verbose

Power info on chassis 0:

System power-supply policy: enable

System power-module redundant(configured): 1

System power usable: 18000 Watts

System power redundant(actual): 2000 Watts

System power allocated: 2620 Watts

System power available: 15380 Watts

SYSTEM POWER USED(CURRENT): 470.00 Watts

System power monitoring unit:

Software version: 100

Type In/Out Rated-Vol(V) Existing Usable Redundant(actual)

---------- ------ ------------ -------- ------ -----------------

PSE9000 AC/DC 220(default) 10 9 1

DC output voltage information:

Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status

---- -------- ------------------ ------------------ -------

1 50.00 53.00 47.00 Normal

2 50.00 53.00 47.00 Normal

DC output current information:

Total current(A): 2.00

Branch Value(A)

------ --------

1/1 N/A

1/2 0.90

1/3 1.40

1/4 0.80

1/5 1.50