Diagnosing transceiver modules – H3C Technologies H3C S12500 Series Switches User Manual

Page 92

Advertising
background image

82

Field Description

Ordering Name

Product code.

# Display the electrical label information about the transceiver plugged in interface GigabitEthernet

3/0/19.

<Sysname> display transceiver manuinfo interface Gigabitethernet 3/0/19

GigabitEthernet3/0/19 transceiver manufacture information:

Manu. Serial Number : 213410A0000054000251

Manufacturing Date : 2008-09-01

Vendor Name : H3C

Table 23 Command output

Field Description

Manu. Serial Number

Serial number generated during commissioning and testing of the transceiver
module

Manufacturing Date

Commissioning date

Diagnosing transceiver modules

The switch provides the alarm function and digital diagnosis function for transceiver modules. When a

transceiver module fails or is not operating normally, you can check the alarms present on the transceiver

module to identify the fault source or examine the key parameters monitored by the digital diagnosis
function, including the temperature, voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules:

Task Command

Remarks

Display alarms present on the transceiver
in a specified interface

display transceiver alarm interface
[ interface-type interface-number ]

If no error occurs, None
is displayed.

Display the present measured values of the
digital diagnosis parameters for the
transceiver in a specified interface

display transceiver diagnosis
interface [ interface-type
interface-number
]

N/A

# Display the alarm information about the transceiver plugged in GigabitEthernet 3/0/1.

<Sysname> display transceiver alarm interface GigabitEthernet 3/0/1

GigabitEthernet3/0/1 transceiver current alarm information:

TX fault

Table 24

shows the alarm information that may occur to the commonly used transceivers.

Table 24 Command output

Field Remarks

SFP

RX loss of signal

Received signals are lost.

TX fault

Transmission error.

RX power high

The received optical power is high.

Advertising