Service LED
The following table explains the status conditions indicated by the different Service LED behaviors.
If two or more status conditions occur simultaneously, the LED displays the behavior for the highest
priority condition.
Priority
Status Condition
LED behavior
1
Identify — The K2 Solo 3G system is being directed
to identify itself by NetCentral or some other
application.
Flashing pattern alternating
Yellow/Green/Red/Off twice a
second
2
Global failure — The K2 Solo 3G system software
has detected a critical error or failure that impacts
record/play operations.
Solid Red
3
Warning — The K2 Solo 3G system software has
detected a problem that requires attention but does
not immediately impact record/play operations. For
example, a fan or power supply has failed but its
redundant partner is maintaining functionality.
Solid Yellow
4
Drive failure — An internal RAID drive has failed.
If RAID 1, the failure does not immediately impact
record/play operations. The redundant partner RAID
drive is maintaining functionality.
Flashing Yellow pattern three times
a second.
5
Drive rebuild — If RAID 1, an internal RAID drive
is rebuilding.
Flashing pattern alternating
Yellow/Green once a second.
5
Normal — The K2 Solo 3G system is healthy and
operating normally.
Off
Disk module LEDs
Each disk module has an LED that indicates status. The LEDs are located on the front bezel. The
following table explains the status conditions indicated by the different LED behaviors. If two or
more status conditions occur simultaneously, the LED displays the behavior for the highest priority
condition. Priority number 1 is the highest priority.
Priority
Status Condition
LED behavior
1
Identify — The drive is being directed to identify
itself by Storage Utility or some other application.
Amber flashing pattern
3
Rebuild — The RAID controller has marked the
drive as rebuilding.
Green flashing pattern twice a
second.
3
Fault — The RAID controller has marked the drive
as faulty.
Red ON solid
3
Offline — The drive is unbound.
Amber ON solid
3
Normal drive activity — The drive is healthy and
disk access is underway.
Green flashing pattern ten times a
second.
06 November 2012
K2 Solo 3G Service Manual
33
Product description