Grass Valley XtenDD v.4.2.4 User Manual
Page 478

5. Application Notes
5 – 5
Operating Instructions – Rev. 1 / 7.2002
5.1.3
OPERATIONAL HINTS
D
Sidepanel menu Install / EBox / Input:
A LAN Input Substitution table can only be defined when in the sidepanel PC
registry the value USERINTERFACE/INPUT_SUBSTAB_SELECTABLE is
set to ’1’. The DD35 application must be closed during this operation.
D
Sidepanel:
The assignment of UPKs has been extended to MasterOnly and SlaveOnly
D
Sidepanel:
In the sidepanel menu Install / Panel / Global you can enter the Simulcast
Mainframe Slave address. Address 0 = inactive. Admissible are the addresses
between 1 and 254
D
For example, the LAN Input Substitution table in the two mainframes should be
put up as described in the figure below. As to the assignment of inputs, an input
number is system–comprehensively clear in the HDTV range as well as also
in the SDTV range:
HD&SD
source
SD only
source
HD only
source
1
2
3
4
5
6
DD35 panel
HD&SD
source
SD only
source
HD only
source
1
2
3
4
5
6
HD35 panel
CP Button Assign
1
2
3
4
5
6
1
2
3
4
1
2
5
6
1
2
3
4
5
6
Slave
Control
MF CMD input
value
LAN Input
Substitution
MF State input
value
HD35 Mainframe
DD35 Mainframe
Master
Control
SD
Master
Control
HD
Figure 4
LAN Input Source Substitution & Input Assignment