6 events menu, Events menu – SMA CLUSTER CONTROLLER User Manual

Page 34

Advertising
background image

Parameter

Explanation

Max. change in case of power
increase

Indicates the maximum change in percentage points per time
interval that occurs once an active power limitation setpoint has
been canceled

Max. change in case of power
reduction

Indicates the maximum change in percentage points per time
interval that occurs once an active power limitation setpoint has
been received

Status configuration

Symbol

Explanation

Corresponds to the value "Logical 1" (= 24 V)

Corresponds to the value "Logical 0" (= 0 V)

4.2.4.6 Events Menu

In the menu Events, Cluster Controller events or inverter events in the system are displayed in the
form of an event log. The Cluster Controller requests the events list from the inverters directly. The
events displayed in each case depend on the inverter that is selected in the system tree, on the user
group, and on the filter settings for the event types (Information, Warning, Error).

Event Types

Symbol

Designation

Explanation

Error

The Error event has existed for some time and
could not yet be remedied.

Incoming error

An Error event has occurred.

Outgoing error

The Error event no longer exists.

Warning

The Warning event has existed for some time
and could not yet be automatically remedied.

Incoming warning

The Warning event has occurred.

Outgoing warning

The Warning event no longer exists.

Information

The Information event has existed for some
time.

Incoming information

The Information event has occurred.

Outgoing information

The Information event no longer exists.

4 User Interface of the Cluster Controller

SMA Solar Technology AG / SMA America, LLC

User Manual

ClusterController-BA-en-14

34