SMA CLUSTER CONTROLLER User Manual

Page 98

Advertising
background image

LED

Status

Cause and corrective measure

Data carrier status (
)

off

The Cluster Controller is starting and no informa-
tion is yet available for data export or for the USB
data carrier.
Corrective measures:

• Wait until the Cluster Controller has

completed the start process and is ready for
operation. Once the start process is
complete, the power LED (

) will glow

green.

No USB data carrier was detected. It is possible
that no USB data carrier is connected or the USB
data carrier is not compatible.
Corrective measures:

• Ensure that a compatible USB data carrier is

connected (see the Cluster Controller
installation manual).

glowing green

The USB data carrier is compatible. The free stor-
age capacity is above 10%.

glowing yellow

The USB data carrier connected to USB port 1 is
compatible but the free storage capacity is no
more than 10%.
Corrective measures:

• Delete files that are no longer required from

the USB data carrier.
or

• Replace the USB data carrier with a USB

data carrier that has sufficient free storage
capacity.

Data carrier status (
)

glowing red

The USB data carrier connected to USB port 1 is
full or write-protected.
Corrective measures:

• If the USB data carrier is full, replace the USB

data carrier.

• If the USB data carrier is write-protected,

remove the write protection or use a USB
data carrier without write protection.

flashing green or
yellow or red

Write/read access is currently being performed
on the USB data carrier.

• Only remove the USB data carrier once the

data carrier status LED is no longer flashing.

18 Troubleshooting

SMA Solar Technology AG / SMA America, LLC

User Manual

ClusterController-BA-en-14

98