2 setting the parameters of an individual device, Setting the parameters of an individual device – SMA CLUSTER CONTROLLER User Manual

Page 45

Advertising
background image

4. Set the desired parameters.
5. Select [Save].

☑ The settings are saved in the Cluster Controller and are then transmitted to all devices of the

affected device class. The save process is displayed on the user interface of the
Cluster Controller via an hourglass symbol and may take several hours if the DC input voltage
in the inverter is too low (e.g. at night).

7.2.2

Setting the Parameters of an Individual Device

The parameters that you are able to set for a device depend on the rights of your user group (see
Section 4.1, page 25).

Procedure:

1. Select the desired device in the system tree and select the menu Settings in the device menu.
2. Select the parameter group that contains the parameter which is to be configured. Note that it

may take a moment to read off the values since they are retrieved directly from the device.

3. Select [Edit].
4. Set the desired parameter.
5. Select [Save].

☑ The settings are saved in the Cluster Controller and are then transmitted to the affected device.

The save process is displayed on the user interface of the Cluster Controller via an hourglass
symbol and may take several hours if the DC input voltage in the inverter is too low (e.g. at
night).

7.3

Deactivating the Webconnect Function of the Inverters

If the Webconnect function is activated for the inverters in the system, you should deactivate the
Webconnect function of the inverters to avoid unnecessary attempts by the inverters to connect with
Sunny Portal. The Webconnect function of the inverters is activated by default.
You have the following options:

• Disabling the Webconnect function for multiple inverters simultaneously
• Disabling the Webconnect function for an individual inverter

Disabling the Webconnect Function for Multiple Inverters Simultaneously

1. Select the system in the system tree and select the menu Settings in the device menu.

☑ The individual device classes are displayed in brackets after the name of the parameter

group, e.g. Device (Communication products). It may take a moment for all the data
to be read out from the devices.

2. Select the parameter group External communication > Webconnect.
3. Select [Edit].

7 Device Configuration

SMA Solar Technology AG / SMA America, LLC

User Manual

45

ClusterController-BA-en-14