3 setting the measured value name, 4 exporting system data to a usb data carrier, Setting the measured value name – SMA CLUSTER CONTROLLER User Manual

Page 51: Exporting system data to a usb data carrier

Advertising
background image

Designation

Explanation

Period

Length of the measurement interval in seconds

TimeStamp

Time stamp at which the average was calculated

8.3

Setting the Measured Value Name

You can have the measured values displayed as follows:

• Technical name of the measured values; example: Metering.TotWhOut
• Name of the measured values as a term; example: Total yield

Procedure:

1. Select the Cluster Controller in the system tree and select the menu Settings in the device

menu.

2. Select the parameter group Data logging > Export.
3. Select [Edit].
4. Set the measured value name:

• In the drop-down list Measured value name in local language, select Yes in order to

display the measured values as a term.

• In the drop-down list Measured value name in local language, select No in order to

display the technical name of the measured values.

5. Select [Save].

8.4

Exporting System Data to a USB Data Carrier

Depending on the available storage capacity of the USB data carrier and the configuration of your
system, the following approximate archival periods for the system data are possible:

Number of connected in-
verters

Approximate archival period

4 GB storage capacity

8 GB storage capacity

5

10 years

20 years

10

5 years

10 years

25

2 years

4 years

50

1 year

2 years

75

9 months

18 months

Requirements:

☐ Maximum storage capacity: 2 TB
☐ The USB data carrier must be formatted in the file system FAT16 or FAT32.

8 Exporting System Data

SMA Solar Technology AG / SMA America, LLC

User Manual

51