6 Main Control PCB Comparison

14

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

Figure 4

Figure 4 A1000 Connection Diagram

+

+



+

+

+

Terminals -, +1, +2, B1, B2 are
for connection options. Never
connect power supply lines to
these terminals

DC link choke

(option)

U

X

Thermal relay

(option)

+

+



+

+

+

+

U

X

S

1

S

2

S

3

S

4

S

5

S

6

S

7

MP

DM

DM

RP

A

1

A

2

A

3

0 V

AC

R

R

S

S



IG

H

1

H

2

HC

Drive

B

1

1

2

B

2

2 k

S

8

SC

0 V

0 V

AC

FM

AM

AC

E (G)

S

1

S

2

<1>

<2>

<3>

<11>

<7>

<12>

<13>

<8>

<10>

<7>

<5>

<4>

+

24 V

+

V

MA

M

1

M

2

MB

MC

Jumper

Braking resistor
(option)

Forward Run / Stop

Reverse Run / Stop

External fault

Fault reset

Multi-speed step 1

Multi-speed step 2

External Baseblock

Jog speed

Multi-function

digtial inputs

(default setting)

Sink / Source mode
selection wire link
(default: Sink)

CN5-C

CN5-B

CN5-A

Option board

Pulse Train Input (max 32 kHz)

Shield ground terminal

Multi-function
analog/pulse

train inputs

Power supply +10.5 Vdc, max. 20 mA

Analog Input 1 (Frequency Reference Bias)

-10 to +10 Vdc (20 k )

Analog Input 2 (Frequency Reference Bias)
-10 to +10 Vdc (20 k )
0 or 4 to 20 mA (250 )

Analog Input 3 / PTC Input (Aux. frequency
reference)
-10 to +10 Vdc (20 k )

V

Power supply, -10.5 Vdc, max. 20 mA

Safety
switch

MEMOBUS/Modbus

comm. RS485/422

max. 115.2 kBps

Safe Disable inputs

Wire

jumper

Open

Safety relay /

controller

Termination resistor

(120 , 1/2 W)

DIP
Switch S2

Fault relay output
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)

Multi-function relay output (During Run)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)

Multi-function pulse train output
(Output frequency)
0 to 32 kHz (2.2 k )

Multi-function analog output 1
(Output frequency)

-10 to +10 Vdc (2mA)
or 4 to 20 mA

EDM (Safety Electronic Device Monitor)

Main Circuit

Control Circuit

shielded line

twisted-pair shielded line

main circuit terminal

control circuit terminal

R/L1

S/L2

T/L3

R

S

T

Main

Switch

Fuse

EMC
Filter

M

3

M

4

Multi-function relay output (Zero Speed)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)

M

5

M

6

Multi-function relay output (Speed Agree 1)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)

SP

SN

<9>

AM

FM

V

I

V

I

DIP Switch S1
A2 Volt/Curr. Sel

DIP Switch S4
A3 Analog/PTC
Input Sel

PTC

AI

Off

On

DIP Switch S2
Term. Res. On/Off

Jumper S3
H1, H2
Sink/Source Sel.

Jumper S5
AM/FM Volt./Curr.
Selection

Terminal board
jumpers and switches

FM

+

AM

<6>

<14>

Ω

Ω

Ω

Ω

Ω

Ω

<13>

Multi-function analog output 2
(Output current)

-10 to +10 Vdc (2mA)
or 4 to 20 mA

Three-Phase
Power Supply
200 to 600 V
50/60 Hz

<15>

<6>

A+
A



B



Z



B+

Z+

a+
a-
b+
b-
z+
z-

FE

IP
IG

TB1

SD

TB2

B track monitor

A track monitor

M

U/T

1

V/T

2

W/T

U

FU

FV

FW

V

W

3

Ground

Cooling fan

PG

M

PG

X3

connectors

(option)

Wiring sequence should shut off
power to the drive when a fault
output is triggered.

(Depending on
model capacity)

Ω

Models CIMR-A 4A930 and
4A1200 are compatible with
12-Phase Rectification.