10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

31

Operation Mode
Selection

Frequency
Reference
Selection

b1-01

1

b1-01

1

b1-01

b1-01

0: Operator

0: Operator

1: Control circuit terminal
(analog input)

1: Control circuit terminal
(analog input)

2: MEMOBUS comm.

2: MEMOBUS comm.

3: Option card

3: Option card

4: Pulse train input

4: Pulse train input

Operation Method
Selection

b1-02

1

b1-02

1

b1-02

b1-02

0: Operator

0: Operator

1: Control circuit terminal

1: Control circuit terminal

2: MEMOBUS comm.

2: MEMOBUS comm.

3: Option card

3: Option card

Stopping Method
Selection

b1-03

0

b1-03

0

b1-03

b1-03

0: Ramp to stop

0: Ramp to stop

1: Coast to stop

1: Coast to stop

2: DC Injection Braking

2: DC Injection Braking

3: Coast to stop with timer 3: Coast to stop with timer

Operation Mode
Selection

Reverse Operation
Selection

b1-04

0

b1-04

0

b1-04

b1-04

0: Reverse enabled

0: Reverse enabled

1: Reverse disabled

1: Reverse disabled

2: Exchange Phase

Operation
Selection for
Setting E1-09 or
Less

b1-05

0

b1-05

0

b1-05

b1-05

0: Run at frequency
reference

0: Run at frequency reference

1: Shut off drive output

1: Shut off drive output

2: Operate by E1-09

2: Operate by E1-09

3: Zero speed

3: Zero speed

Digital Input Scan
Time

b1-06

1

b1-06

1

b1-06

b1-06

0: 2 ms - 2 scans

0: 1 ms - 1 scan

1: 5 ms - 2 scans

1: 1 ms - 2 scans

Operation
Selection After
Switching to
Remote Mode

b1-07

0

b1-07

0

b1-07

b1-07

0: Cycle Run command

0: Cycle Run command

1: Accept external Run
cmd

1: Accept external Run cmd

Run Command
Selection while in
Programming
Mode

b1-08

0

b1-08

0

b1-08

b1-08

0: Disabled.

0: Disabled.

1: Enabled - Run cmd
always accepted

1: Enabled - Run cmd always accepted

Run Command at
Power Up

b1-17

0

0: Prohibited 1: Allowed
Change b1-17 to 1 to match F7 (Caution: drive will run at power on)

DC Injection
Braking

DC Injection
Braking Start
Frequency

b2-01

0.5 Hz

b2-01

0.5 Hz*

*Determined by parameter A1-02, Control Method Selection

DC Injection
Braking current

b2-02

50%

b2-02

50 %

DC Injection
Braking Time at
Start

b2-03

0.00 s

b2-03

0.00 s

DC Injection
Braking Time at
Stop

b2-04

0.00 s

b2-04

0.50 s

*

*Determined by the control mode selected.

Magnetic Flux
Compensation
Value

b2-08

0%

b2-08

0%

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000