10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

33

PID Control

PID Output Level
Selection

b5-09

0

b5-09

0

b5-09

b5-09

0: Normal

0: Normal

1: Reverse

1: Reverse

PID Output Gain
Setting

b5-10

1.0

b5-10

1.00

Minimum setting units vary.

PID Output
Reverse Selection

b5-11

0

b5-11

0

b5-11

b5-11

0: Negative PID output
triggers zero limit

0: Negative PID output triggers zero limit

1: Rotation direction
reverses with negative PID
output.

1: Rotation direction reverses with negative PID output.

PID Feedback
Reference Missing
Detection
Selection

b5-12

0

b5-12

0

b5-12

b5-12

0: No Detection

0: No Detection

1: Alarm

1: Alarm and MFO (@PID enable only)

2: Fault

2: Fault and MFO (@PID enable only)

3: Multi-function output only (no display indication, @
PID enable/disable)

4: An alarm is triggered and the drive continues
running, @ PID enable/disable.

5: Fault is triggered and output is shut off, @ PID
enable/disable.

PID Feedback Loss
Detection Level

b5-13

0 %

b5-13

0 %

PID Feedback Loss
Detection Time

b5-14

1.0 s

b5-14

1.0 s

PID Control

PID Sleep
Function Start
Level

b5-15

0.0 Hz

b5-15

0.0 Hz

PID Sleep Delay
Time

b5-16

0.0 s

b5-16

0.0 s

PID Accel/Decel
Time

b5-17

0.0 s

b5-17

0.0 s

Dwell Function

Dwell Reference at
Start

b6-01

0.0 Hz

b6-01

0.0 Hz

Dwell Time at Start

b6-02

0.0 s

b6-02

0.0 s

Dwell Frequency
at Stop

b6-03

0.0 Hz

b6-03

0.0 Hz

Dwell Time at Stop

b6-04

0.0 s

b6-04

0.0 s

Droop Control

Droop Control
Level

b7-01

0.0 %

b7-01

0.0 %

Droop Control
Delay Time

b7-02

0.05 s

b7-02

0.05 s

Energy Saving
Control

Energy Saving
Control Selection

b8-01

0

b8-01

0*

b8-01

b8-01

0: Energy Saving disabled 0: Energy Saving disabled
1: Energy Saving enabled

1: Energy Saving enabled

*Determined by parameter A1-02.

Energy Saving
Gain

b8-02

1.0

b8-02

*

Determined by parameter A1-02.

Energy Saving
Control Filter Time
Constant

b8-03

Varies by

kVA

b8-03

*

Dependent on parameters A1-02, C6-01, and o2-04.

Energy Saving
Coefficient Value

b8-04

Varies by

kVA

b8-04

*

Dependent on parameters o2-04 and C6-01. Value changes automatically if E2-11 is
manually changed or changed by Auto-Tuning.

Power Detection
Filter Time

b8-05

20 ms

b8-05

20 ms

Search Operation
Voltage Limit

b8-06

0 %

b8-06

0 %

Zero Servo

Zero Servo Gain

b9-01

5

b9-01

5

Zero Servo
Completion Width

b9-02

10

b9-02

10

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000