10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

51

Stall Prevention
Function

Stall Prevention
Selection during
Acceleration

L3-01

1

L3-01

1

L3-01

L3-01

0: Disabled

0: Disabled

1: General purpose

1: General purpose

2: Intelligent

2: Intelligent

Stall Prevention
Level during
Acceleration

L3-02

*

L3-02

150 %

**

*Varies by Duty Rating
**Upper limit is determined by C6-01 and L8-38.

Stall Prevention
Limit during
Acceleration

L3-03

50 %

L3-03

50 %

Stall Prevention
Selection during
Deceleration

L3-04

1

L3-04

1

L3-04

L3-04

0: Disabled

0: Disabled

1: General purpose

1: General purpose

2: Intelligent

2: Intelligent

3: Stall Prevention with
braking resistor

3: Stall Prevention with braking resistor

4: Overexcitation Deceleration

5: Overexcitation Deceleration 2

Stall Prevention
Selection during
Run

L3-05

1

L3-05

1

L3-05

L3-05

0: Disabled

0: Disabled

1: Enabled (Decel Time 1) 1: Enabled (Decel Time 1)
2: Enabled (Decel Time 2) 2: Enabled (Decel Time 2)

Stall Prevention
Level during Run

L3-06

*

L3-06

**

*Varies by duty rating (Defaults:HD = 150 %, ND = 120 %)
**Upper limit is determined by C6-01 and L8-38.

Overvoltage
Supression
Function Selection

L3-11

0

L3-11

0

L3-11

L3-11

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Stall Prevention
Function

F7: Overvoltage
Suppression
Voltage Level
A1000: Target DC
Bus Voltage for

Overvoltage
Suppression and
Stall Prevention

L3-12

380 V

*

L3-17

370 V

*

*Double values for 400 V class drives.

Frequency
Detection

Speed Agreement
Detection Level

L4-01

0.0 Hz

L4-01

0.0 Hz

Speed Agreement
Detection Width

L4-02

2.0 Hz

L4-02

*

*Dependent on parameter A1-02

Speed Agreement
Detection Level (+/
-)

L4-03

0.0 Hz

L4-03

0.0 Hz

Speed Agreement
Detection Width
(+/-)

L4-04

2.0 Hz

L4-04

*

*Dependent on parameter A1-02

Frequency
Reference Loss
Detection
Selection

L4-05

0

L4-05

0

L4-05

L4-05

0: Stop

0: Stop

1: Run at L4-06 PrevRef

1: Run at the level set to L4-06

In A1000, the setting range for the frequency reference when the reference is lost
(L4-06) is 0 to 100 % (default: 80 %)

Reference
Detection

Frequency
Reference Level at
Loss Frequency

L4-06

80.0 %

L4-06

80.0 %

Fault Restart

Number of Auto
Restart Attempts

L5-01

0 times

L5-01

0 times

Auto Restart
Operation
Selection

L5-02

0

L5-02

0

L5-02

L5-02

0: No Fault Relay

0: Fault output not active

1: Fault Relay Active

1: Fault output active during restart attempt

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000