Table 21 Control Circuit Terminal Size and Wire Gauge

Power Supply

Series

Capacity

Terminal Signal

Terminal Screw

Tightening Torque

lb-in

(N m)

Possible Gauges

AWG (mm

2

)

Recommended

Gauges AWG

(mm

2

)

200 V Class
400 V Class

F7

All capacities

FM, AC, AM, A1,
A2, A3, +V, -V,
S1, S2, S3, S4, S5,
S6,S7, S8, SN, SC,
SP, RP, MA, MB,
MC, M1,M2, M3,
M4, M5, M6,

Phoenix type

4.2 to 5.3

(0.5 to 0.6)

Stranded wire: 26 to

16

(0.14 to 1.5)

18

(0.75)

MP, RP, R+, R-, S+,
S-, IG

Phoenix type

4.2 to 5.3

(0.5 to 0.6)

Stranded wire:

26 to 16

(0.14 to 1.5)

18

(0.75)

E (G)

M3.5

7.0 to 8.8

(0.8 to 1.0)

20 to 14

(0.5 to 2.0)

12

(1.25)

200 V Class
400 V Class

A1000

All capacities

FM, AC, AM, P1,
P2, PC,
SC, SN, SP, A1, A2,
A3, +V, -V,
S1, S2, S3, S4, S5,
S6,S7, S8,
MA, MB, MC,
M1-M6

M3

4.4 to 5.3

(0.5 to 0.6)

stranded wire:

24 to 16

(0.2 to 1.0)

solid wire:

24 to 16

(0.2 to 1.5)

Ferrule-Type:

24 to 20 (0.25 to 0.5)

Bare Wire: 18 (0.75)

Ferrule-Type: 20 (0.5)

MP, RP, R+, R-, S+,
S-, IG
DM+, DM-, H1, H2,
HC

M3

4.4 to 5.3

(0.5 to 0.6)

Bare Wire: 18 (0.75)

Ferrule-Type: 20 (0.5)

E (G)