background image

10 Appendix 2 Parameter Cross Reference

52

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

Overtorque
Detection

Torque Detection
Selection 1

L6-01

0

L6-01

0

L6-01, L6-04

L6-01, L6-04

0: Disabled

0: Disabled

1: oL3 detection only
active during speed agree,
operation continues after
detection

1: oL3 detection only active during speed agree,
operation continues after detection

2: oL3 detection always
active during run,
operation continues after
detection

2: oL3 detection always active during run, operation
continues after detection

3: oL3 detection only
active during speed agree,
output shuts down on an
oL3 fault

3: oL3 detection only active during speed agree, output
shuts down on an oL3 fault

4: oL3 detection always
active during run, output
shuts down on an oL3
fault

4: oL3 detection always active during run, output shuts
down on an oL3 fault

5: UL3 detection only
active during speed agree,
operation continues after
detection

5: UL3 detection only active during speed agree,
operation continues after detection

6: UL3 detection always
active during run,
operation continues after
detection

6: UL3 detection always active during run, operation
continues after detection

7: UL3 detection only
active during speed agree,
output shuts down on an
oL3 fault

7: UL3 detection only active during speed agree, output
shuts down on an oL3 fault

8: UL3 detection always
active during run, output
shuts down on an oL3
fault

8: UL3 detection always active during run, output shuts
down on an oL3 fault

Torque Detection
Level 1

L6-02

150 %

L6-02

150 %

Torque Detection
Time 1

L6-03

0.1 s

L6-03

0.1 s

Overtorque
Detection

Torque Detection
Selection 2

L6-04

0

*

L6-04

0

*

*See the description for L6-01; replace “oL3” and “UL3” with “oL4” and “UL4”,
respectively

Torque Detection
Level 2

L6-05

150 %

L6-05

150 %

Torque Detection
Time 2

L6-06

0.1 s

L6-06

0.1 s

Torque Limit

Forward Torque
Limit

L7-01

200 %

L7-01

200 %

Reverse Torque
Limit

L7-02

200 %

L7-02

200 %

Forward
Regenerative
Torque Limit

L7-03

200 %

L7-03

200 %

Reverse
Regenerative
Torque Limit

L7-04

200 %

L7-04

200 %

Torque Limit
Integral Time
Constant

L7-06

200 ms

L7-06

200 ms

Torque Limit
Control Method
Selection During
Accel/Decel

L7-07

0

L7-07

0

L7-07

L7-07

0: Proportional Control
(60 Hz VT2)

0: Proportional control

1: Integral Control
(50 Hz HST1)

1: Integral control

Hardware
Protection

Internal Dynamic
Braking Resistor
Protection
Selection (ERF)

L8-01

0

L8-01

0

L8-01

L8-01

0: Not Provided

0: Disabled

1: Provided

1: Enabled

Overheat
Pre-Alarm Level

L8-02

95°C

L8-02

*

*Determined by parameters C6-01 and o2-04

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000