10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

35

Speed Control
(ASR)

ASR Proportional
Gain 1

C5-01

20.00

C5-01

20.00

*

*Determined by the control mode selected (A1-02). Default shown here is for when
suing Closed Loop Vector Control.

ASR Integral Time
1

C5-02

0.500 sec

C5-02

0.500 sec

*

ASR Proportional
Gain 2

C5-03

20.00

C5-03

20.00

*

ASR Integral Time
2

C5-04

0.500 sec

C5-04

0.500 sec

*

ASR Limit

C5-05

5.0 %

C5-05

5.0 %

ASR Primary
Delay Time
Constant

C5-06

0.004 sec

C5-06

0.004 sec

*

*Determined by the control mode selected (A1-02). Default shown here is for when
suing Closed Loop Vector.

ASR Gain
Switching
Frequency

C5-07

0.0 Hz

C5-07

0.0 Hz

ASR Integral Limit

C5-08

400%

C5-08

400%

Carrier Frequency

Drive Duty
Selection

C6-01

0

C6-01

1

Parameter contents differ between F7 and A1000

C6-01

C6-01

0: Heavy Duty

0: Heavy Duty

1: Normal Duty 1

1: Normal Duty

2: Normal Duty 2

Carrier Frequency
Selection

C6-02

Varies by

kVA

C6-02

*

C6-02

C6-02

0: Low Noise PWM

1: 2.0 kHz

1: 2.0 kHz

2: 5.0 kHz

2: 5.0 kHz

3: 8.0 kHz

3: 8.0 kHz

4: 10.0 kHz

4: 10.0 kHz

5: 12.5 kHz

5: 12.5 kHz

6: 15.0 kHz

6: 15.0 kHz

7 to A: Swing PWM 1-4

B to E: No setting possible

F: User-set

F: User-set

*Dependent on A1-02, C6-01, and o2-04.

Carrier Frequency
Upper Limit

C6-03

Varies by

kVA

C6-03

*

*Dependent on C6-02.

Carrier Frequency
Lower Limit

C6-04

Varies by

kVA

C6-04

*

*Dependent on C6-02.

Carrier Frequency
Proportional Gain

C6-05

0

C6-05

*

*Dependent on C6-02.

Frequency
Reference

Frequency
Reference 1

d1-01

0.00 Hz

d1-01

0.00 Hz

Frequency
Reference 2

d1-02

0.00 Hz

d1-02

0.00 Hz

Frequency
Reference 3

d1-03

0.00 Hz

d1-03

0.00 Hz

Frequency
Reference 4

d1-04

0.00 Hz

d1-04

0.00 Hz

Frequency
Reference 5

d1-05

0.00 Hz

d1-05

0.00 Hz

Frequency
Reference 6

d1-06

0.00 Hz

d1-06

0.00 Hz

Frequency
Reference 7

d1-07

0.00 Hz

d1-07

0.00 Hz

Frequency
Reference 8

d1-08

0.00 Hz

d1-08

0.00 Hz

Frequency
Reference 9

d1-09

0.00 Hz

d1-09

0.00 Hz

Frequency
Reference 10

d1-10

0.00 Hz

d1-10

0.00 Hz

Frequency
Reference 11

d1-11

0.00 Hz

d1-11

0.00 Hz

Frequency
Reference 12

d1-12

0.00 Hz

d1-12

0.00 Hz

Frequency
Reference 13

d1-13

0.00 Hz

d1-13

0.00 Hz

Frequency
Reference 14

d1-14

0.00 Hz

d1-14

0.00 Hz

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000