10 appendix 2 parameter cross reference – Yaskawa F7 to A1000 User Manual

Page 40

Advertising
background image

10 Appendix 2 Parameter Cross Reference

40

YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide

Analog Monitor
Card

Channel 1 Monitor
Selection

F4-01

2

F4-01

102

F4-01, F4-03, H4-01,
H4-04, o1-01

F4-01, F4-03, H4-01, H4-04, o1-01

01: Frequency reference

101: Frequency reference

02: Output frequency

102: Output frequency

03: Output current

103: Output current

05: Motor speed

105: Motor speed

06: Output voltage
reference

106: Output voltage reference

07: Main circuit DC
voltage

107: Main circuit DC voltage

08: Output power

108: Output power

09: Torque ref (Internal)

109: Torque ref (Internal)

15: Freq ref, A1 voltage

113: Freq ref, A1 voltage

16: Freq ref, A2 voltage

114: Freq ref, A2 voltage

17: Freq ref, A3 voltage

115: Freq ref, A3 voltage

18: Secondary current (Iq)

601: Secondary current (Iq)

19: Motor excitation
current (Id)

602: Motor excitation current (Id)

20: Output after soft start

116: Output after soft start

21: ASR input

603: ASR input

22: ASR output

604: ASR output

24: PID feedback amount

501: PID feedback amount

26: Output voltage ref
(Vq)

605: Output voltage ref (Vq)

27: Output voltage ref
(Vd)

606: Output voltage ref (Vd)

Analog Monitor
Card

Channel 1 Monitor
Selection

F4-01

2

F4-01

102

32: ACR output (q-axis)

607: ACR output (q-axis)

33: ACR output (d-axis)

608: ACR output (d-axis)

36: PID input amount

502: PID input amount

37: PID output amount

503: PID output amount

38: PID setpoint

504: PID setpoint

44: ASR output , no filter

625: ASR output , no filter

45: Feed Forward output

626: Feed Forward output

Terminal V1
Monitor Gain

F4-02

100.0 %

F4-02

100.0 %

Terminal V2
Monitor Selection

F4-03

3

*

F4-03

103

*

*See the comments column for F4-01.

Terminal V2
Monitor Gain

F4-04

50.0 %

F4-04

50.0 %

Terminal V1
Monitor Bias

F4-05

0.0 %

F4-05

0.0 %

Terminal V2
Monitor Bias

F4-06

0.0 %

F4-06

0.0 %

Terminal V1
Signal Level

F4-07

0

F4-07

0

F4-07

F4-07

0: 0 to 10 V

0: 0 to 10 V

1: -10 to +10 V

1: -10 to +10 V

Terminal V2
Signal Level

F4-08

0

F4-08

0

F4-08

F4-08

0: 0 to 10 V

0: 0 to 10 V

1: -10 to +10 V

1: -10 to +10 V

Parameter Name

F7

A1000

Setting

Parameter

Default

Parameter

Default

F7

A1000