Ratings Comparison
NEC HP Ratings for 230V Heavy Duty Models
GPD506/P5 230V Models
F7 240V Models
Constant Torque
(n116=0)
Heavy
Duty
(C6-01=0)
NEC
HP
230V
NEC
Amps
GPD506/P5
Model
CIMR-P5U
Output
Amps Fc kHz
Overload%
CT
1 minute
F7
Model
CIMR-F7U
Output
Amps
Fc
kHz
Overload %
HD
1 minute
0.5 2.2 20P41 3.2
15 150
0.75 3.2 20P41 3.2
15 150
20P41 3.2 2 150
20P71 4.1 2 150
1 4.2 20P71 6
15
150
1.5 6 20P71 6
15
150
2 6.8 21P51 8
15
150
21P51 7 2 150
3 9.6 22P21 11
15
150
22P21 9.6 2 150
23P71
15
2
150
5 15.2 23P71 17.5
15
150
7.5 22 25P51 25
10 150
25P51 23 2 150
10 28 27P51 33
10 150
27P51 31 2 150
15 42 20111 49
10 150
20111 45 2 150
20 54 20151 64
10 150
20181 64 15 150
20151 58 2 150
25 68 20221 83
15 150
20181 71 2 150
30 80
20221 85 2 150
40 104 20301 104
10 150
20371 128 10 150
20301 115 2 150
50 130 20451 154
10 150
20371 145 2 150
60 154
20451 180 2 150
75 192 20551 198 8 150
20551 215 2 150
100 248 20751 250 8 150
20751 283 2 150
125 312
- -
-
-
20901 346 2 150
150 360
- -
- -
21100
415
2