GPD506/P5 to F7 Specification Differences

Feature

or Function

Item

Yaskawa GPD506/P5

Yaskawa F7

Performance Features

240V

0.75 to 125HP (VT)

0.5 to 150HP (ND)

1

480V

0.75 to 500HP (VT)

0.5 to 500HP (ND or HD)

1

HP Range

Note: The voltage rating in
the “Item” column is
generalized. Refer to the
Service Conditions section for
rated input voltage
requirements.

600V

2 to 200HP (VT)

Available w/GPD506/P5

Not Available in F7

Overload Rating

% for Minutes

150% for 1 min (CT)

200% peak

120% for 1 min (VT)

180% peak

150% for 1 min (HD)
110% for 1 min (ND)

200% peak

PWM Carrier Frequency

Range

See Carrier Frequency Table

See Carrier Frequency Table

Max. Output Frequency

Hz 400Hz

300 Hz (HD) 400 Hz (ND)

1000 Hz optional

V/f 40:1

40:1

V/f w/PG

Not Applicable

50:1

Open Loop

Not Applicable

200:1

Speed Range

Closed Loop

Not Applicable

1000:1

V/f w/PG

Not Applicable

0.2%

Open Loop

Not Applicable

0.2%

Speed Regulation

Closed Loop

Not Applicable

0.01%

Starting Torque at Low Speed

% @ Hz

100% @ 3Hz (V/f)

150% @ 1.0Hz (V/f)

150% @ 0.5Hz (OLV)

150% @ 0.3Hz (Closed loop)

Protective Features

Torque Limit / Current Limit
Stall Prevention

-

-- Stall Prevention During

Accel/Run/Decel (V/F)

-- Undertorque Warning and

Output Action

-- Torque Limit Accel/Run/Decel

Stall Prevention During

Accel/Run/Decel (V/F)

Torque Limit in 4 Quadrants

(OLV)

Over/Under Torque Detection

Heat Sink Temperature Fault

Fault Action

Coast, Ramp, Continue

Coast, Ramp, Continue or

Continue with reduced speed

Design Features

Display

2 Line x 16 Character LCD

5x7 Segment LED (Optional)

5 Line x 16 Character LCD (Std)

5x7 Segment LED (Optional)

Qty of keys

7

11

Language 1

7

(w/LCD)

Keypad Design

Copy Function

No

Yes

1

HD=Heavy Duty, ND=Normal Duty

Advertising