The Cable Status includes the following items: Table 4-38 Description of the Cable Status.

Item

Description

• Pair

The twist pair of the UTP cable. The pair groups as follow:

A (Pin 1,2)

B (Pin 3,6)

C (Pin 4,5)

D (Pin 7,8)

• Length[m]

When properly terminated, Cable Diagnostics reports the approximate cable length in meters of

each of the four cable pair A, B, C, and D.

• Status

The cable test results. Possible values are:

• Proper - The cable passed the test.

• Open - The cable is connected on only one side or there is no cable connected to the port

• Short - A short has occurred in the cable. With 10/100BASE link, the status of Pair C and Pair

D will be “Short”.

• Abnormal termination – An improper termination be detected. Proper termination of Cat5

cable requires 100Ω

differential impedance between the positive and negative cable

terminals. IEEE STD 802.3 allows for a termination of as large as 115Ω or as small
as 85Ω. If the termination falls out of this range, it is reported as falls an anomalous
termination.