PLANET WGSD-10020 User Manual

Page 533

Advertising
background image

User’s Manual of WGSD-10020 Series

533

DC Disconnect

DC Disconnect detection involves measurement of current. Naturally, a disconnected PD stops consuming current, which can

be inspected by the PSE. The PSE must therefore disconnect power within 300 to 400 ms from the current flow stop. The lower

time boundary is important to prevent shutdown due to random fluctuations.

AC Disconnect

This method is based on the fact that when a valid PD is connected to a port, the AC impedance measured on its terminals is

significantly lower than in the case of an open port (disconnected PD).

AC Disconnect detection involves the induction of low AC signal in addition to the 48 VDC operating voltage. The returned AC

signal amplitude is monitored by the PSE at the port terminals. During normal operation, the PD's relatively low impedance

lowers the returned AC signal while a sudden disconnection of this PD will cause a surge to the full AC signal level and will

indicate PD disconnection.

Advertising
This manual is related to the following products: